Ozone Analyzer 106-L

The Model 106 series of ozone monitors was designed specifically for the industrial ozone industry to cover four different ozone concentration ranges by varying the optical path length.  The ranges are: -L (low, 0-100 ppm); -M (medium, 0-1,000 ppm); -MH (medium high, 0-10,000 ppm, 0-1 vol%) and -H (0-20 wt%, 0-14 vol%).  The Model 106 series is designed as an “ozone monitor on a board” in which nearly all of the components are mounted directly to the printed circuit board with very few wire connections, making these instruments highly robust and very easy to service.  As seen in the images above, all models are available in a standard enclosure, Industrial enclosure, or with no enclosure for OEM applications for those who want to mount the instrument in their own enclosure or use it as a component of a larger system. For more details on OEM applications see: Model OEM-106.  Configurations for multi-channel sampling are available for Models 106-L, 106-M, and 106-MH.

The Model 106-L Ozone Monitor is designed for measurements of ambient ozone concentrations down to very low ppb levels. However, because of the large dynamic range of our ozone monitors, the Model 106-L also can be used for accurate measurements of ozone at concentrations up to 100 ppm (100,000 ppb).  The accuracy and precision of this instrument is comparable to our our original Model 202 Ozone Monitor widely used for field measurements by atmospheric researchers`

The Model 106-L Ozone Monitor is recommended for workplace health and safety monitoring where ozone is being produced and used in a wide range of industrial applications such as water treatment, food processing, aquaculture, fruit and vegetable warehouses, and others.

Specification:

Measurement Principle UV Absorption at 254 nm, single beam
Federal Equivalent Method (FEM) Yes
Measurement Interval 2 s
Linear Dynamic Range 0-100,000 ppb (0-100 ppm)
Resolution 0.1 ppb
Precision (1σ for 10-s average; aka rms noise) Greater of 1.5 ppb or 2% of Reading
Limit of Detection (10-s average, 2σ) 3.0 ppb
Accuracy Greater of 1.5 ppb or 2% of Reading
Baseline Drift < 3 ppb/day, < 6 ppb/year
Sensitivity Drift < 1%/day, < 3%/year
Calibration NIST Traceable; Annual calibration recommended
Measurement Time, Frequency 2 s, 0.5 Hz
Data Averaging Options 10 s, 1 min, 5 min, 1 hr
Response Time, 100% of Step Change For 2-s output: 4 s, 2 data points
For 10-s output: 20 s, 2 data points
Adaptive Filter Available, user-specified parameters
Data Logger Capacity 32,736 lines (10 s avg. = 3.8 days; 5 min avg = 113 days)
Data Transfer Baud Rate 2400, 4800, 19200
Ozone Units ppb, pphm, ppm, µg m-3, mg m-3
Temperature Units oC, K
Pressure Units mbar, torr
T and P Corrected Yes
DewLine™ for Humidity Control Yes
Operating Temperature Range 0 to 50oC
Operating Altitude Range 0-13.5 km (0-25 km option)
Flow Rate Minimum required: 0.6 L/min; Nominal: 1 L/min; Maximum: 1.5 L/min
Digital Data Outputs USB, RS232, LCD Display
Analog Data Outputs 0-2.5 V Analog, 4-20 mA, User-Scalable in Menu
Power Requirements 100-240 VAC, 50/60 Hz
11-28 V DC, nominally 500 mA at 12 V DC, 6 watt
Relays with 2 Setpoints Two available:
Relay 1 responds based on user’s ozone set points
Relay 2 responds based on user’s ozone set points OR responds based on diagnostics (T, P, flow, lamp voltage)
Four relays for Industrial models
Bluetooth Option Available Yes
Flow-Through Option Available Yes
Multi-Channel Options Available Yes, 3-channel and 6-channel configurations for 106-L, -M, and -MH
Size Standard Case: 3.6 x 7.9 x 9.4 inches (9 x 20 x 24 cm)
OEM Version: 2.5 x 7 x 9 in (6.2 x 17.8 x 22.9 cm)
Industrial Version: 16 x 14 x 9.3 in (40.7 x 35.7 x 23.6 cm) H x W x D
Weight Standard Case: 4.2 lb (1.9 kg)
OEM Version: 2.8 lb (1.3 kg)
Industrial Version: ~14 lb (6.3 kg) depending on multi-channel options
Options Battery, Particle Filter, Bluetooth, Flow-Through Configuration, Multi-Channel Configurations, High-Altitude Package
Features
  • Measurement based on UV absorption
  • Low power consumption; can be battery operated (optional external lithium-ion battery)
  • Internal data logger with real-time clock
  • ​2-s measurement interval
  • On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m, 5 m, 1 hr, and user-defined adaptive filter
  • USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure
  • Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user-selected units and scaling factors
  • Two 2-level relays for control purposes (e.g., control of ozone source or turn warning light on and off); Four relays on Industrial enclosure models
  • Long-life pump (15,000 hr)
  • Bluetooth option for wireless data transmission
  • Optional configurations for 3-channel or 6-channel air sampling for 106-L, -M, and -MH

Share On:

Share on facebook
Share on linkedin
Share on whatsapp
Share on twitter

Related Products

Shopping cart