PHILIPS HS1 SEMI-AUTOMATIC AED

Ready to act. Ready to go: HS1 is virtually ready to go the moment it arrives. With the Ready-Pack configuration, the HS1 AED is positioned inside the carry case, with Adult SMART Pads Cartridge and battery already installed and with a spare Adult SMART pads cartridge in place. Just pull the green tab to launch the initial self-test and press the green On/Off button, which activates voice instructions and visual icons.

Start quickly. Treat confidently: HS1 includes features to help guide the treatment of sudden cardiac arrest with easy setup, clear voice commands and a real time metronome for performing CPR. HS1 conducts a series of automatic self-tests daily, weekly and monthly, including testing the pads, internal circuitry, waveform delivery and battery capacity so you can be assured when the moment comes, you will have a partner by your side.

Easy as 1-2-3: We’ve equipped HS1 with integrated SMART Pads that will provide feedback to the AED so it can adapt its voice instructions to your actions and your pace. The system won’t announce the next step until you are ready. Prompts are repeated and rephrased if needed and include additional instructions to aid understanding. The system senses when the special Infant/Child SMART Pads cartridge is installed and automatically adjusts CPR instructions and shock energy to a level more appropriate for infants and children under 25 kg or 55 lbs. or 0-8 years old.

  • Waveform : SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedance
  • Defibrillation peak current – Adult : 32 A (150 J nominal) into a 50 ohm load
  • Defibrillation peak current – Pediatric : 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge)
  • Shock-to-Shock Cycle Time : Typically less than 20 seconds between shocks in a series
  • Quick Shock : Able to deliver a shock after the end of a CPR interval, typically in eight seconds
  • Type : 9 Volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells
  • Capacity : Minimum 200 shocks or 4 hours of operating time
  • Standby life : Typically, 4 years when battery is installed and when stored and maintained as per directions
  • Adult SMART Pads cartridge : M5071A defibrillation pads for patients over 8 years of age or 25 kg (55 lbs.) and over
  • Infant/Child SMART Pads cartridge : M5072A defibrillation pads for patients 0-8 years of age and under 25 kg (55 lbs) by prescription only
  • Active surface area : 85 cm2 (13.2˝2) each
  • Cable length : Adult SMART Pads: 137.1 cm (54˝) Infant/Child SMART Pads: 101.6 cm (40˝)
  • Approvals: Approved to Latest ERC/AHA Guidelines, CE, IEC & EN Approved.